TC0660 FCMthe FCM seems to be responsible for various miscellaneous functions. CPU address mapping, communication between the CPU and FDP, generating CPU interrupts, address buffering for the ESP's RAM, etc.
| 1 | GND | |
|---|---|---|
| 2 | D19 | CPU data (16-bit) |
| 3 | D18 | |
| 4 | D17 | |
| 5 | D16 | |
| 6 | A19 | CPU address high |
| 7 | A18 | |
| 8 | A17 | |
| 9 | A16 | |
| 10 | GND | |
| 11 | A15 | |
| 12 | A7 | CPU address low |
| 13 | A6 | |
| 14 | A5 | |
| 15 | A4 | |
| 16 | A3 | |
| 17 | A2 | |
| 18 | A1 | |
| 19 | A0 | |
| 20 | VCC | |
| 21 | ||
| 22 | ||
| 23 | ||
| 24 | ||
| 25 | ||
| 26 | ||
| 27 | ||
| 28 | ||
| 29 | ||
| 30 | GND | |
| 31 | ||
| 32 | ||
| 33 | ||
| 34 | ||
| 35 | ||
| 36 | ||
| 37 | ||
| 38 | VCC | |
| 39 | ||
| 40 | VCC |
| 41 | GND | |
|---|---|---|
| 42 | ||
| 43 | ||
| 44 | ||
| 45 | ||
| 46 | ||
| 47 | ||
| 48 | otis.e | |
| 49 | otis.bclk | |
| 50 | GND | |
| 51 | otis.ser1 | |
| 52 | esp.ser0 | |
| 53 | otis.ser2 | |
| 54 | esp.ser1 | |
| 55 | otis.ser3 | |
| 56 | esp.ser2 | |
| 57 | esp.ser3 | |
| 58 | dac.data | |
| 59 | GND | |
| 60 | VCC | |
| 61 | ||
| 62 | A0 | ESP RAM data/addr latch |
| 63 | D9 | |
| 64 | A1 | |
| 65 | D10 | |
| 66 | A2 | |
| 67 | D11 | |
| 68 | A3 | |
| 69 | D12 | |
| 70 | GND | |
| 71 | A4 | |
| 72 | D13 | |
| 73 | A5 | |
| 74 | D14 | |
| 75 | A6 | |
| 76 | D15 | |
| 77 | A7 | |
| 78 | D16 | |
| 79 | esp.gate | |
| 80 | VCC | |
| 81 | GND | |
|---|---|---|
| 82 | ||
| 83 | ||
| 84 | fdp.29 | CPU address to FDP? |
| 85 | fdp.28 | |
| 86 | fdp.26 | |
| 87 | fdp.25 | |
| 88 | fdp.24 | |
| 89 | fdp.23 | |
| 90 | GND | |
| 91 | fdp.22 | CPU address to FDP? |
| 92 | fdp.21 | |
| 93 | fdp.20 | |
| 94 | fdp.19 | |
| 95 | fdp.18 | |
| 96 | fdp.17 | |
| 97 | fda.27 | FDA something |
| 98 | fda.28 | |
| 99 | fda.26 | |
| 100 | VCC | |
| 101 | ||
| 102 | ic14.cs | CPU work RAM chip selects |
| 103 | ic15.cs | |
| 104 | ic16.cs | |
| 105 | ic17.cs | |
| 106 | fio.118 (chip select?) | |
| 107 | cpu.dsack0 | |
| 108 | cpu.dsack1 | |
| 109 | ic64.9 | |
| 110 | GND | |
| 111 | fdp.16 | |
| 112 | fdp.14 | |
| 113 | fdp.13 | |
| 114 | fdp.12 | |
| 115 | cpu.ipl2 | |
| 116 | cpu.ipl1 | |
| 117 | cpu.ipl0 | |
| 118 | ||
| 119 | cart.C04 | |
| 120 | VCC | |
| 121 | GND | |
|---|---|---|
| 122 | otis.e | |
| 123 | otis.serlr | |
| 124 | ||
| 125 | cpu.avec | |
| 126 | pal2.22 (interrupt ack) | |
| 127 | cart.A90 | |
| 128 | cart.C04 | |
| 129 | ||
| 130 | GND | |
| 131 | 30mhz clock in | |
| 132 | VCC | |
| 133 | cpu.reset | |
| 134 | cpu.siz0 | |
| 135 | cpu.siz1 | |
| 136 | cpu.rw | |
| 137 | cpu.ds | |
| 138 | cpu.as | |
| 139 | GND | |
| 140 | VCC | |
| 141 | pal1.22 (addr map C-F) | |
| 142 | pal1.20 (addr map 6) | |
| 143 | pal1.19 (addr map 4) | |
| 144 | D31 | CPU data (16-bit) |
| 145 | D30 | |
| 146 | D29 | |
| 147 | D28 | |
| 148 | D27 | |
| 149 | D26 | |
| 150 | GND | |
| 151 | D25 | |
| 152 | D24 | |
| 153 | D23 | |
| 154 | D22 | |
| 155 | D21 | |
| 156 | D20 | |
| 157 | ||
| 158 | ||
| 159 | ||
| 160 | VCC | |